LF KGD-PSC (Grooving/Cut-off toolholder) DCSFMS WF CW DCSFMS CDX LF Right-hand shown Polygpon size WF CW DCSFMS Toolholder dimensions Groove width CW (mm) Available grooving depth (mm) Description Avail- ability RL DCSFMS CDX Dimensions (mm) LF Width W (mm) Spare part Clamp bolt LF WF CDX Top coolant MIN MAX KUA-KPC4-KGD & -2T17 2 17 KUA-KPC5-KGD & -2T17 C4 40 60 27 17 C5 50 60 35 17 2.0 3.0 KUA-KPC4-KGD & -3T20 C4 40 65 27 20 3 20 KUA-KPC5-KGD & -3T20 C5 50 65 35 20 3.0 4.0 KUA-KPC6-KGD & -3T20 C6 60 65 45 20 KUA-KPC4-KGDR -4T25 C4 40 70 27 25 4 25 KUA-KPC5-KGDR -4T25 C5 50 70 35 25 4.0 5.0 KUA-KPC6-KGDR -4T25 C6 60 70 45 25 KUA-KPC4-KGDR -5T25 C4 40 70 27 25 5 25 KUA-KPC5-KGDR -5T25 C5 50 70 35 25 5.0 6.0 KUA-KPC6-KGDR -5T25 C6 60 70 45 25 The recommended clamping torque is 6.5 Nm and the maximum coolant supply pressure is 80 bar. CDX dimension shows available grooving depth (When CDX dimension is 20 mm or more, maximum grooving depth with 2 corners is 18 mm). HH5X16 Applicable inserts GDM type GDG type : Available www.kyocera-unimerco.com The information contained in this brochure is current as of September 2021. Duplication or reproduction of any part of this brochure without approval is prohibited. TZE00201 © 2021 KYOCERA Corporation